Jenn-Air JVD0303GS Installation Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 15
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
9
External Venting Dimensional Planning
Single Unit with 6" (15.2 cm) External Discharge
This conguration accommodates one or two 15" (38.1 cm)
cooktops, one on either or each side of the downdraft intake.
Center Line of
Downdraft Inlet
Center Line of
Blower Discharge
A
A. 6
23
/
32
" (16.2 cm)
Option: Two Downdrafts with Single 8" (20.3 cm)
External Discharge
This conguration accommodates one or two 15" (38.1 cm)
cooktops and a 30" (76.2 cm) or 36" (91.4 cm) cooktop.
As shown, the 30" (76.2 cm) or 36" (91.4 cm) (note: 30"
[76.2 cm] cooktop requirement shown, add 6" [15.2 cm] to
the 18
9
/
64
" [46.1 cm] dimension for a 36" [91.4 cm] cooktop)
cooktop would be located between downdraft intakes and
the 15" (38.1 cm) on the left side of the larger cooktop.
A second 15" (38.1 cm) cooktop can be located on the right
side of the 30"
(76.2 cm)/36" (91.4 cm) cooktop.
For a 30" (76.2 cm)/36" (91.4 cm) cooktop and single 15"
(38.1 cm) cooktop on the right hand side of the cooktop, the
dimensions shown are to be applied as a mirror image.
Y-Transition Ducting Kit: W11180669
A. 33
7
/
8
" (86 cm)
B. 34
5
/
64
" (86.5 cm)
C. 15
47
/
64
" (40 cm)
D. 18
9
/
64
" (46.1 cm)
E. 6
23
/
64
" (16.2 cm)
Center Line of
Downdraft Intake
Center line of
Blower Intake
Center line of
Blower Intake
Center Line of
Cutout
Center Line of
Downdraft intake
Cutout
Opening
Depth
Cutout Opening
Width
F
45° 6" (15.2 cm) Elbow
A
B
E
D
H
G
C
Option: Two Downdrafts with Single 8" (20.3 cm)
External Discharge
This conguration accommodates three 15" (38.1 cm)
cooktops, one between downdraft intakes and one on each
side of the down draft intakes.
Order Y-Transition Ducting Kit: W11180669
Center Line
Cutout
Center Line
Blower Intake
Center Line
Downdraft Intake
Center Line
T- Ducting Transition
Center Line
Downdraft Intake
Cutout
Opening
Depth
Cutout Opening
Width
A
B
C
D
F. Center line of blower intake
G. Center line of Y ducting transition
H. 6" (15.2 cm) ducting to size
A. 19
5
/
64
" (48.8 cm)
B. 15
29
/
32
" (40.4 cm)
C. 6
23
/
64
" (16.2 cm)
D. Center line blower intake
Page view 8